nyx: finer control of fan when temp is high

This commit is contained in:
CTCaer 2024-02-16 16:07:27 +02:00
parent 6e6f5f8eed
commit e96e74c72a

View File

@ -1,5 +1,5 @@
/* /*
* Copyright (c) 2018-2023 CTCaer * Copyright (c) 2018-2024 CTCaer
* *
* This program is free software; you can redistribute it and/or modify it * This program is free software; you can redistribute it and/or modify it
* under the terms and conditions of the GNU General Public License, * under the terms and conditions of the GNU General Public License,
@ -1330,11 +1330,13 @@ static void _update_status_bar(void *params)
max17050_get_property(MAX17050_VCELL, &batt_volt); max17050_get_property(MAX17050_VCELL, &batt_volt);
max17050_get_property(MAX17050_Current, &batt_curr); max17050_get_property(MAX17050_Current, &batt_curr);
// Enable fan if more than 46 oC. // Enable fan if more than 41 oC.
u32 soc_temp_dec = (soc_temp >> 8); u32 soc_temp_dec = (soc_temp >> 8);
if (soc_temp_dec > 51) if (soc_temp_dec > 51)
set_fan_duty(102); set_fan_duty(102);
else if (soc_temp_dec > 46) else if (soc_temp_dec > 46)
set_fan_duty(76);
else if (soc_temp_dec > 41)
set_fan_duty(51); set_fan_duty(51);
else if (soc_temp_dec < 40) else if (soc_temp_dec < 40)
set_fan_duty(0); set_fan_duty(0);